2. Tarmoqqa ulangan pv tizimlarini loyihalashga tegishli standartlar
|
bet | 18/20 | Sana | 15.05.2023 | Hajmi | 1.25 Mb. | | #59740 |
Bog'liq gibrid10.1 soyaning ta'siri
Ipdagi modullar sonini tanlashda ehtiyot bo'lish kerak, chunki soyalash natijasida yuqori haroratlarda maksimal quvvat nuqtasi kuchlanishi inverterning minimal ish kuchlanishidan past soyalash kamayguncha inverterning yopilishiga olib keladi. Soyaning energiya rentabelligiga ta'sirini aniq taxmin qilish qiyin bo'lishi mumkin va dizaynerlar a dan foydalanishlari kerak mijozga energiya rentabelligini ta'minlashda mos dastur yoki konservativ bo'ling.
Ishlangan Misol 18
Ushbu qo'llanma davomida biz namunaviy tizim uchun quyidagi ma'lumotlarni aniqladik:
Parray-stc = 6050 Wp
ƒtemp = 0.828
ƒman = 0.97
ƒdirt = 0.9
Htilt = 1846.9kWh/m2
ηinv = 0.96 (96%)
ηpv_inv = 0.97 (97%)
ηinv-sb = 0.99(99%)
E sys = Parray_STC × f temp × f mm × f dirt × Htilt × ηpv × ηpv_inv × ηinv × ηinv-sb
Esys = 6050 x 0.828 x 0.97 x 0.9 x 1846.9x 0.96 x 0.97 x 0.99
Esys = 7445974 Wh yoki 7445.97kWh
11. Maxsus Hosil
Maxsus energiya rentabelligi kVt / soat uchun kVt / soat bilan ifodalanadi
va u quyidagicha hisoblanadi:
SY _ =
Agar turli mintaqalardagi tizimlarning ishlashini taqqoslash kerak bo'lsa, soyaning yo'qolishi taxmin qilinishi kerak va energiya rentabelligini hisoblashdan chiqarib tashlandi. Bu tizimning yillik energiya ishlab chiqarishiga asoslangan. Tarmoqqa etkazib beriladigan quyosh massivining AC energiyasi
Esys yuqoridagi formulada haqiqiy DSQ esa massivning reytingi Parray_STC yuqoridagi formulada.
|
| |