• B10.9.1 RAID - Windows Compatibility
  • B10.9.3.2 - B10.9.3.5 See B10.9.3.1 B10.9.4 RAID - Windows Experience B10.9.4.1 All external SCSI connectors are labeled with ANSI approved icon for bus type
  • B10.9.4.3 DELETED B10.9.4.4 DELETED
  • B10.9.4.6 Option ROMS support INT 13
  • B10.8.5 Media Changer Devices - FAQs




    Download 0,89 Mb.
    bet168/188
    Sana21.03.2017
    Hajmi0,89 Mb.
    #429
    1   ...   164   165   166   167   168   169   170   171   ...   188

    B10.8.5 Media Changer Devices - FAQs


    See B10.1.5.

    B10.8.R Media Changer Devices - Future Requirements


    See B10.1.R.

    B10.9 RAID


    All general requirements in B1.0 are included by reference.
    All bus-specific requirements in B2.0 are included by reference.
    All general storage requirements in B10.1 are included by reference.

    Note: If this device is implemented on a client system, compatibility testing is required.

    B10.9.1 RAID - Windows Compatibility

    B10.9.1.1 SCAM is disabled by default, if SCSI device

    See B10.3.1.1

    B10.9.2 RAID - Industry Standards


    See B10.1.2 and B10.3.2.

    B10.9.3 RAID - Quality

    B10.9.3.1 Pass WHQL tests- See B1.3, B10.1.4.7.

    See “RAID Devices” and “RAID Controller” in the HCT documentation.
    B10.9.3.2 - B10.9.3.5

    See B10.9.3.1

    B10.9.4 RAID - Windows Experience

    B10.9.4.1 All external SCSI connectors are labeled with ANSI approved icon for bus type

    See B10.3.4.5.1
    B10.9.4.2 Requirements in B10.1.4 do not apply for RAID Cluster Devices

    This program only verifies basic cluster failover functionality requirements; all features and Windows Experience testing is completed when the product goes through the prerequisite Logo testing for the device type.
    B10.9.4.3 DELETED
    B10.9.4.4 DELETED
    B10.9.4.5 RAID subsystem supports manual replacement of failed drive

    The RAID subsystem must provide for manual replacement of a failed drive without shutting down or halting the system. The subsystem must also allow lost data to be rebuilt without interfering with system operations beyond some decreased performance of drive array access.
    B10.9.4.6 Option ROMS support INT 13

    Option ROMs for RAID controllers implemented on systems or as add-in controller cards must fully support INT 13.

    See A1.1.4.9