Slit Beam Profiler Application changelog:
V1.0 Oct-14-2005
Initial release
V1.1 Jan-20-2006
- Message title "USERPOWER_POPUP_TITLE" corrected
- Actual power for user power calibration corrected
- Zoom and pan also applicable to vertical scale
- Variable clip level instead two fixed
- 2D graph configuration panel added including
- vertical logarithmic scale
- marking of maximum positions (centroid or peak)
- maximum autocenter function
- marking of zero and clip level
- settable zoom
- 3D graph configuration including
- top view default
- zoom
- gray scale
- contour
- VISA, Driver and Firmware version check at program start
- Larger font for selected parameter value
- Rolling average implemented
- Display of selected parameter with 6 decimal digits if peak power < 0.01
V2.0 Sep-15-2006
- Beam width correction for 13.5% clip level added
- M² measurement added
- BP parameter structure and display extended
- Pass/Fail panel and functionality added
- Printing capability added
V2.1 Nov-15-2006
- Bug removed: Display text was 'Centroid' overwritten by 'Peak Power'
- Pass/Fail test result also visible in main panel
- Beam quality designator k changed to K
V2.2 Feb-26-2007
- Support of UV Beam Profiler BP104-UV and BP109-UV
- Separate man/auto switches for gain, bandwidth and offset settings
- Bug fix: M2 measurements accepts now wavelengths out of Beam Profiler range for calculation
- M2 divergence unit changed from rad into mrad
- M2: in case of very low divergence (parallel beam) a linear fit is done automatically
- M2: a hyperbolic fit (with lens) and a successive linear fit (w/o. lens) can be combined to an approximation of the unfocussed beam
- Implementation of DataSocket data transfer for BP and M2 results
V2.3 Apr-02-2008
- Support for Windows Vista
- Adjustable 'Field of View' for 3D graph, displays small beams at high resolution
- Manual updated with M
V2.4 Jun-04-2009
- Support of new models BP104-IR2 and BP109-IR2
- Settable wavelength range for BP and M2 extended
- Fonts changed for better readability on Japanese OS
- For M2: Power unit switches to 'mW' if it was 'digit' before -> prevents erroneous beam diameter readings
V2.5 Jun-05-2009 - internal release
- Calibration panel does not close after offset value calibration - this is fixed.
V2.6 Jan-22-2010
- Modifications to cope with VXIpnp driver V2.4.
V2.7 Apr-23-2010
- USB drivers signed to support installation on Windows VISTA / 7 systems.
- Instrument driver files included in distribution package.
V2.8 Jun-02-2010
- Bug removed: missing analysis support added to distribution kit
- Corrected printer icon
|