Development of an combined energy complex consisting of a micro-hydroelectric power plant and a solar photoelectric plant for the conditions of Uzbekistan




Download 3,13 Mb.
Pdf ko'rish
bet4/7
Sana29.05.2024
Hajmi3,13 Mb.
#256807
1   2   3   4   5   6   7
Bog'liq
Development of an combined energy complex consisti

0
500
1000
1500
0
10
20
30
40
50
P
ow
er
, W
Angle 
experiment theoretical
420.7
587.8
684.4
705.7
716.5
745.8
920.6
1000
1050.7
1080.9
0
200
400
600
800
1000
1200
0
0.05
0.1
0.15
0.2
0.25
P
, W
𝑄

𝑚
3/

experiment theoretical
, 05027 (2024)
BIO Web of Conferences
AQUACULTURE 2023
https://doi.org/10.1051/bioconf/20248405027
84
6


Fig. 6. 
Combined Energy Device Installation Location
To convert direct current into alternating current, a CH-4000W inverter manufactured by 
the Republic of China was used. 
Lighting systems for the area where the family business is located, a refrigerator, an 
electric stove for cooking, video surveillance devices and modem devices for connecting to 
the Internet were connected, that is, a load with a total power of 3796 W. 
The operating modes of the loads are shown in Table 1. Since there was no need for a 
daylighting system, electric lamps were used in the evenings. Loads such as a video 
surveillance system, a modem device, and a refrigerator worked constantly connected. 
During the day, the main load was the electric stove for cooking, and it worked for more than 
10 hours. When measuring the electricity supplied by the inverter with an electric meter in 
the period from 08:00 to 19:00, it was found that 30 kWh of electricity was supplied. 
Table 2.
Operating modes of consumers. 
Loads 
Froom 08-00 to 19-00 
Froom 19-00 to 08-00 
Power, 

Quan
tity, 
units 
Total 
power, 

Working 
time, 
hour 
Power, 

Qua
ntity, 
units 
Total 
power, 

Working 
time, 
hour 
Lighting system 
(electric lamp) 
15 

30 

15 
24 
360 

12 

12 

12 
18 
216 

10 

10 

10 

50 

Video 
surveillance 
system 
400 

400 
11 
400 
400 
13 
Internet modem
20 

20 
11 
20 
20 
13 
Elektr stove for 
cooking 
2 500 

2 500 
10 
Fridge 
250 

250 

250 
250 

Total power, W 
3 222 
1 296 
From 19:00 in the evening until 08:00 in the morning, the combined energy device began 
to operate with a maximum load of 1296 W. The electricity generated by the Archimedes 
screw turbine was used to power consumers through an inverter and to charge the batteries, 
delivering a total of 10 kWh of electricity. 
Using measuring instruments, the daily values of the output voltage and current of the 
solar power plant and micro-hydroelectric power station were determined. The graph of daily 
capacity utilization of KUE is shown in Figure 7. 
, 05027 (2024)
BIO Web of Conferences
AQUACULTURE 2023
https://doi.org/10.1051/bioconf/20248405027

Download 3,13 Mb.
1   2   3   4   5   6   7




Download 3,13 Mb.
Pdf ko'rish

Bosh sahifa
Aloqalar

    Bosh sahifa



Development of an combined energy complex consisting of a micro-hydroelectric power plant and a solar photoelectric plant for the conditions of Uzbekistan

Download 3,13 Mb.
Pdf ko'rish