Ibm® Sterling Connect: Direct
|
bet | 22/47 | Sana | 24.03.2021 | Hajmi | 84,26 Kb. | | #13516 |
Fix Availability Date: 19 May 2015
High Impact: N
Reported Severity: 4
4.7.0.3_iFix008: RTC468875 / APAR IT09460
Description of Issue: Sterling Control Center and the Application Interface for Java (AIJ) fail to update Secure+ configurations after applying 4.7.0.3_iFix001.
Description of Fix: Updated the path to the JRE in the CMGR to point to the new JRE installation directory.
Fix Availability Date: 15 June 2015
High Impact: N
Reported Severity: 2
4.7.0.3_iFix009: RTC469611 / APAR IT09613
Description of Issue: CSPA320W warning occurring even when Secure+ was already disabled on the Snode by default: The Snode allowed a Pnode override to disable Secure+.
Description of Fix: Updated the condition for CSPA320W to occur.
Fix Availability Date: 23 June 2015
High Impact: N
Reported Severity: 4
4.7.0.3_iFix010: RTC472434 / APAR IT10446
Description of Issue: Process goes immediately from TIMR RE to HOLD HS on a TCP/IP timeout (LIPT011I, OS error 10060) and does not retry.
Description of Fix: Removed the condition that had triggered HOLD HS, allowing the process to retry as expected.
Fix Availability Date: 31 July 2015
High Impact: N
Reported Severity: 3
4.7.0.3_iFix011: RTC467270 / APAR IT09724
Description of Issue: Secure+ transfers failing when Windows is sending and the negotiated buffer size (RU Size) is less than 16384 bytes.
Description of Fix: Updated the buffer size calculation.
Fix Availability Date: 06 August 2015
High Impact: N
Reported Severity: 2
4.7.0.3_iFix012: RTC471699 / APAR IT10556
Description of Issue: Connect:Direct API commands over a secure connection fail after upgrading the JRE in Connect:Direct Browser, Sterling Control Center or other application using the Application Interface for Java (AIJ).
Description of Fix: Fixed.
Fix Availability Date: 10 August 2015
High Impact: N
Reported Severity: 2
4.7.0.3_iFix013: RTC460012 / APAR IT11122
Description of Issue: When a process fails with an exception response, like LSMG622I and SCPA024I, it was moved to the HOLD queue but with a wrong status of HS. As a side effect of this status, the process will get restarted at the next node startup.
Description of Fix: Updated exception handling to correctly move the process to HOLD HE.
Fix Availability Date: 09 September 2015
High Impact: N
Reported Severity: 2
4.7.0.3_iFix014: RTC477370 / APAR IT11470
Description of Issue: Add the ability to create a configuration report from the CLI.
Description of Fix: Updated the CLI (Direct.exe) and its internal help command to support the new parameter 'cdconfig' on the traceon command. The configuration report will be written to a file named cdconfig.txt created in the same folder as the specified trace file. For example, enter the following command line in the CLI to create a configuration report in C:\Temp\cdconfig.txt:
traceon file=C:\Temp\dummy.cdt config;
|
| |