• Description of Fix
  • Description of Issue
  • Fix Availability Date
  • Workaround
  • Ibm® Sterling Connect: Direct




    Download 84.26 Kb.
    bet8/47
    Sana24.03.2021
    Hajmi84.26 Kb.
    #13516
    1   ...   4   5   6   7   8   9   10   11   ...   47
    Fix Availability Date: 14 May 2014

    High Impact: N

    Reported Severity: 4
    4.7.0.0_iFix003: RTC423150 / APAR IT02000

    Description of Issue: CSPA204E written to statistics when Sterling Control Center Secure Connection settings are changed.

    Description of Fix: Fixed.

    Fix Availability Date: 13 May 2014

    High Impact: N

    Reported Severity: 4
    4.7.0.0_iFix004: RTC423196 / APAR IT02002

    Description of Issue: Silent Installation fails when included Secure+ Client Key Certificate configuration. Error: SPCL103E rc=8 Invalid key word "CipherSuite".

    Description of Fix: Fixed.

    Fix Availability Date: 13 May 2014

    High Impact: N

    Reported Severity: 3
    4.7.0.0_iFix005: RTC424498 / APAR IT01934 / CVE-2014-0963

    Description of Issue: Vulnerability related to Record Processing in TLS 1.0 and later which can result in high CPU Utilization that requires a system reboot to resolve.

    Description of Fix: Updated the version of GSKit.

    Fix Availability Date: 30 May 2014

    High Impact: Y

    Reported Severity: 2
    All iFixes and fix packs listed above are accumulated in fix pack 1 (4.7.0.1).

    iFixes after 4.7.0.1
    4.7.0.1_iFix001: RFE 401559 (ID 40797) / APAR IT03451

    Description of Issue: Simple clicking OK button in CD Secure+ Admin tool, without changing any value is updating the node's record file.

    Description of Fix: Updated SPAdmin to only write the record when the node was changed.

    Fix Availability Date: 29 July 2014

    High Impact: N

    Reported Severity: 5
    4.7.0.1_iFix002: RTC408632 / RFE 405966 (ID 42671) / APAR IT00728

    Description of Issue: Sterling Connect:Direct for Windows Total Max Sessions enforcement

    Description of Fix: Added a new initialization parameter sess.total. It works similar to sess.pnode.max and sess.snode.max, except that it limits the maximum concurrent connections for all remote nodes in total. Valid numeric values are 1 to 510. The initial value if not specified is the sum of sess.pnode.max plus sess.snode.max.

    Fix Availability Date: 05 August 2014

    High Impact: N

    Reported Severity: 5
    4.7.0.1_iFix003: RTC435753 / APAR IT04317

    Description of Issue: CSPA303E, CSPE004E and CSPE005E errors occurring sporadically under high concurrency and when Strong Password Encryption (SPE) is enabled.

    Description of Fix: Resolved a threading issue and updated the version of GSKit. Improved exception handling to avoid a potential crash situation.

    Workaround: Temporarily disabled SPE.

    Fix Availability Date: 09 September 2014

    High Impact: N

    Reported Severity: 2
    4.7.0.1_iFix004: RTC436568 / RFE 400238 (ID 40159) / APAR IT04447

    Description of Issue: Enable millisecond timestamp on statistics records in Sterling Control Center.

    Description of Fix: The Connect:Direct Windows server now stores millisecond time resolution on some of the existing time stamps saved in its statistics logs. Please note that a Connect:Direct API client can choose whether or not to display the extra millisecond time resolution characters now available.



    Download 84.26 Kb.
    1   ...   4   5   6   7   8   9   10   11   ...   47




    Download 84.26 Kb.