• Description of Fix
  • Ibm® Sterling Connect: Direct




    Download 84,26 Kb.
    bet9/47
    Sana24.03.2021
    Hajmi84,26 Kb.
    #13516
    1   ...   5   6   7   8   9   10   11   12   ...   47
    Fix Availability Date: 29 September 2014

    High Impact: N

    Reported Severity: 5
    4.7.0.1_iFix005: RTC437894 / APAR IT04504

    Description of Issue: Sterling Control Center was unable to catch up on statistics with a busy Connect Direct Windows node. Select Statistics queries started to take longer and longer to complete. The Connect Direct Windows node responded slowly and solidDB started to create lots of temporary files (sxs*.*).

    Description of Fix: Widely increased the performance for the type of Select Statistics queries initiated by Sterling Control Center. These queries specify the LIMIT parameter and do not include wildcards or SFILE/DFILE.

    Workaround: See the following Technote at https://www.ibm.com/support/entdocview.wss?uid=swg21682729: Many solidDB® temp files are being created and it caused the Connect:Direct Disk to fill up and CD statistic cannot be collected.


    Download 84,26 Kb.
    1   ...   5   6   7   8   9   10   11   12   ...   47




    Download 84,26 Kb.