• I R I Q (AMALIY
  • II. Amaliy topshiriqni bajaring. 2 . 1 - topshiriq. Elektr energiyasi iste’moli.
  • Infommunikatsiya qurilmalari elektr ta’minoti” fanidan amaliyot




    Download 25.66 Kb.
    bet1/3
    Sana16.12.2023
    Hajmi25.66 Kb.
    #120845
      1   2   3
    Bog'liq
    1-amaliy
    file, 10sinfIvariyant, Trees Growing, texnologik jarayonlarni modellashtirish asoslari, Abdulhamid4, Mavzu, Mavzu sovuq haroratli kunlarda yo’l poyini qurishning o’ziga xo-fayllar.org, 716106-Yo`l poyini ustki yuzasini va yon bag’rini pardozlashda , 2-Maruza, 1-Maruza.ppt

    O‘ZBEKISTON RESPUBLIKASI AXBOROT TEXNOLOGIYALARI VA KOMMUNIKATSIYALARINI RIVOJLANTIRISH VAZIRLIGI


    MUHAMMAD AL-XORAZMIY NOMIDAGI
    TOSHKENT AXBOROT TEXNOLOGIYALARI UNIVERSITETI
    “Energiya ta’minlash tizimlari” kafedrasi

    INFOMMUNIKATSIYA QURILMALARI ELEKTR TA’MINOTI”


    fanidan


    AMALIYOT


    TOPSHIRIQ №1

    Bajardi : Dasturiy injiniring ta’lim yo‘nalishi


    312-21 guruh talabasi Hasanov Murodillo
    Qabul qildi : Saidova Gulchehra
    Toshkent 2023
    INFOMMUNIKATSIYA QURILMALARI ELEKTR TA’MINOTI” fandan


    1 T O P SH I R I Q (AMALIYOT)
    I. So’rovnoma savollariga javob berish.
    1.1 - so’rovnoma. Elektr energiyasi iste’moli.
    Men Buxoro viloyati Romitan tumani Hazortut MFY 225-uyda istiqomat qilaman.
    1. Xonadoningiz qancha kuchlanishda elektr energiyasi iste’mol qiladi – 220V.
    2. 1 oyda (to’lov amalga oshirilgan muddatda) xonadoningiz qancha elektr energiyasi iste’mol qiladi - 130 kVt.soat.
    3. 1 oyda (to’lov amalga oshirilgan muddatda) elektr energiyasiga qancha so’m to’ladingiz – 40 000 so’m.
    4. 1 kVt soat energiyani narxi qancha : 295 so’m/kVt*s.
    5. Xonadoningizdagi elektr yuklamalarni umumiy quvvat qancha 1 ~ 2 kVt.
    6. Qanday avtomatik uzgich sizning xonadoningizda o’rnatilgan: 5 A.
    II. Amaliy topshiriqni bajaring.
    2.1 - topshiriq. Elektr energiyasi iste’moli. (9 - variant)
    Misol: Quvvatlari Pnom1=25 Vt; Pnom2=40 Vt va kuchlanishi Unom=127V bo’lgan ikkita elektr lampasi, kuchlanishi Unom=220V bo’lgan elektr tarmog’iga ketma-ket ulangan. Lampalarda kuchlanish qanday taqsimlanadi va ikkala lampa normal ishlay oladimi?
    Yechish. Quvvat va kuchlanishning nominal qiymatlari buyicha xar bir lampaning nominal tokining qiymatlarini aniqlaymiz:
    Inom1 = Pnom1 / Unom = 25/127 = 0.197 A.
    Inom2 = Pnom2 / Unom = 40/127 = 0.315 A.
    Lampa spiralining qarshiligi:
    rnom1 = Unom / Inom1 = 127 / 0,197 = 645 Om.
    rnom2 = Unom / Inom2 = 127 / 0.315 = 403 Om.
    Lampalar 220 Volt kuchlanishga ketma-ket ulanganda zanjirdagi tok:
    I = U / (rном1 +rном2) = 220 / (645+403) = 0.21 А.
    Lampalardagi kuchlanish lampalarning qarshiliklariga to’g’ri proporsional taqsimlanadi, ya’ni :
    U₁ = I * rnom1 = 0.21 A * 645 Om = 135.45 V
    U2 = I * rnom2 = 0.21 A * 403 Om = 84.55 V
    Xulosa. Quvvati Rnom1=645Vt bo’lgan lampa nominal kuchlanishidan yuqoriroq kuchlanishda birmuncha yoruqroq yonib, tezda kuyishi mumkin. Quvvati Rnom2=403Vt bo’lgan lampa nominal kuchlanishidan pastroq kuchlanishda xira yonadi.