• Server Runtime
  • Server Configuration
  • Server Event Log
  • Native Client Interfaces
  • Utilities
  • Drivers
  • TOP Server Release Notes (5.8.109.0) February 21, 2012




    Download 176,31 Kb.
    bet13/20
    Sana25.09.2020
    Hajmi176,31 Kb.
    #11681
    1   ...   9   10   11   12   13   14   15   16   ...   20

    TOP Server Release Notes (5.8.109.0) February 21, 2012




    Server Admin


    • Moved the User Manager from a separate dialog that was launched from the Administration menu to a tab in the Settings dialog (which is located through the Administration menu by clicking Settings | User Manager).

    • Enhanced the User Manager by adding granularity to specify whether users can modify channels, devices, and tags. Added a built-in user profile called “Data Client” to control whether clients can access Dynamic (Native) Tags.

    • Removed the “Allow clients to write to system level tags” option from the Runtime Options tab in the Settings dialog. Added it to the permissions list of the Data Client profile in the User Manager tab in the Settings dialog.

    • Updated the Event Log tab in the Settings dialog to provide grid control for Event Log persistence enhancements.

    • Streamlined host resolution to eliminate the need for user configuration settings. These settings have been removed from the Server Administration UI. The updated implementation is quicker to react to changes in network address mapping but the change should be transparent to existing applications. The drivers that use host resolution are as follows: Bristol BSAP, ControlLogix Ethernet, DNP Ethernet, Modbus Ethernet, MT Connect, Ping, Siemens TCP/IP, and SNMP.

    Server Runtime


    • Channel Diagnostics are now referred to as “Communications Diagnostics”. As part of this change, Communications Diagnostics can now be displayed at the device level.

    • Fixed font corruption occurring on some non-English OS configurations that was caused by the unexpected destruction of a needed resource. Applied dynamic font replacement to the Device View in order to correct the inconsistent appearance under these same conditions.

    Server Configuration


    • Fixed an issue where a deadlock could occur in Communications Diagnostics when diagnostics were published from a driver at the same time that a project was automatically saving.

    • Fixed the following issues in the GUI:

      • Fixed performance issues when processing Runtime updates after Automatic Tag Generation (ATG) completes and includes a large number of nested tag groups.

      • Fixed an issue where display of the Alias Name dialog or Tag Browser window was slow.

      • Fixed the slow processing of multi-tag deletion.

      • Fixed the incorrect advancement of the progress gauge on the Status Bar.

      • Fixed the missing view updates in listen-only clients when processing a Runtime update that signals the addition of multiple devices or individual tags.

      • Fixed the Tag Browser window’s position restoration logic so that it works properly in multi-monitor situations.

      • Prevented the Multiple Tag Generator Tool from replacing the active selection out from under the tag dialog after tag generation. This was causing problems in situations where a tag was selected in the dialog before the Multiple Tag Generator Tool was invoked.

      • Fixed a failure to undo a CSV import.

    Server Event Log


    • Added new persistence settings to support extended data storage. These settings are configured from the Event Log tab in the Settings dialog.



    Server Installation


    • A user is now allowed to transfer licenses between Virtual Machines. Eliminated the Virtual Machine (VM) detection and User Agreement UI seen prior to 5.8 when installing on a VM.



    Native Client Interfaces


    Wonderware FastDDE/SuiteLink Interface


    • Added the ability to configure the Application Name in the FastDDE/SuiteLink tab (located through the Configuration by clicking File | Project Properties).


    OPC UA Server Interface


    • Updated the GUI to limit the length of the “Max Notifications Per Publish” and “Max Retransmit Queue Size” property controls to agree with the length of the maximum value that is allowed for these properties.

    • Fixed OPC UA server performance issues introduced in version 5.7. As part of this fix, the OPC UA server interface no longer meets OPC compliancy. Compliancy will be addressed at a further date.



    Utilities


    License Activation Utility


    • Updated all title bars to display the product name instead of the company name.

    • Eliminated the restriction of software license transfers on Virtual Machines.

    Plug-Ins


    DataLogger


    • Fixed an issue where the plug-in filled empty “Database Field Name” fields with “Unknown” on xml load.

    • Fixed an issue where xml projects containing expressions would fail to load in server version 5.7.


    Media Level Redundancy


    • Fixed an issue where modifications made to the Primary device’s Channel Name and/or Device Name caused issues with its ability to switch over to the Secondary when a monitor item was defined.



    Drivers


    All Drivers


    • Fixed the blank message box displayed by some drivers (following an attempt to change a setting that is not allowed to change) while data collection is active on a channel or device.

    • Added device-level diagnostic support to most drivers.

      • Note: The following drivers do not support device-level diagnostics:

        • AB Unsolicited Ethernet

        • Advanced Simulator

        • Dataforth IsoLynx

        • DDE Client

        • DNP Master Serial

        • DNP Master Ethernet

        • GE Ethernet Global Data

        • GE Focas1 Ethernet

        • GE Focas1 HSSB

        • Hilscher Universal

        • InTouch Client

        • Memory Based

        • Mettler Toledo Serial

        • Modbus Unsolicited Serial

        • ODBC Client

        • OPC DA Client

        • OPC UA Client

        • Simulator

        • Siemens TCP/IP Unsolicited Ethernet

        • Telemecanique Uni-Telway Slave


    Allen-Bradley DH+


    • Fixed an issue that was introduced in the 5.7 release where the Runtime crashed due to an unknown resource scope.


    Allen-Bradley ControlLogix Ethernet


    • Fixed the incorrect font that was applied to the Channel Wizard dialog “Suggestions” on Chinese language operating systems.

    • Added support for the following pre-defined tags: @REVISION, @STATUS, @MODE, @VENDORID, @PRODUCTCODE, @PLCTYPE, and @PROCESSORNAME.

    • Fixed an issue where the driver could report incorrect data to client applications if the value read was greater than 262,136 bytes (such as in an array of 65535 DINTs). This only occurred on devices configured for Physical Blocking Mode.

    • Updates for RSLogix version 20.

      • The following was included for offline automatic tag generation:

        • Added the new pre-defined types DCAF_INPUT and DCA_INPUT.

        • Added several new members to the following (per V20 changes): AXIS_CIP_DRIVE, AXIS_CONSUMED, AXIS_GENERIC, AXIS_GENERIC_DRIVE, AXIS_SERVO, AXIS_SERVO_DRIVE, AXIS_VIRTUAL, COORDINATE_SYSTEM, MOTION_INSTRUCTION, and MOTION_GROUP

    • Performance statistics are now properly disabled when non-ControlLogix models are selected.


    Allen-Bradley ControlLogix Slave Ethernet


    • Initial release of the new driver. It is licensed with either the Allen-Bradley Driver Suite or the Manufacturing Suite, and requires that new licenses be issued for access (pre-5.8 activations are not compatible with this driver). Current AB Suite or Manufacturing Suite license holders click here for details on accessing this driver.

    • This driver is intended for customers that require the use of CIP Data Table Read and Write Messages from the Logix family of controllers and need to communicate with a driver in an OPC server.


    Beckhoff TwinCAT



    • Corrected issues that prevented the Port Number device property from persisting in sheet mode. Corrected issues in wizard mode that caused changes to the Port Number to be lost after leaving the page and returning to wizard mode.

    • For TwinCAT PLC models, do not attempt to read device version information if the API dlls are missing (or if generating tags from a symbol file).

    • Optimized communications with TwinCAT PLC models by minimizing the overhead previously put on the device.

    • Automatically generated tags no longer allow clients to override the assigned data type.


    Bristol/IP (BSAP over IP)


    • Increased the maximum number of channels from 16 to 256.


    Custom Interface Driver (CID)


    • Fixed a failure to update String Array tags.


    DNP Master Ethernet


    • Updated refresh logic to improve usability with projects that reference more than a hundred channels.


    DNP Master Serial


    • Updated refresh logic to improve usability with projects that reference more than a hundred channels.


    Fisher ROC Serial


    • Added support for Channel Serialization, Inter-Device Delay, and RTS Line Control.

    • Updated the Operator Identification tab in Device Properties to be more consistent with ROCLINK configuration software.

    • Consolidated Tag Import Settings under a single tab in Device Properties.


    Fisher ROC Plus Serial


    • Added support for Channel Serialization, Inter-Device Delay, and RTS Line Control.

    • Updated the Operator Identification tab in Device Properties to be more consistent with ROCLINK configuration software.

    • Consolidated Tag Import Settings under a single tab in Device Properties.



    OPC DA Client


    • Changed the default update rate from 50 milliseconds to 1000 milliseconds.


    GE Focas1 High Speed Serial Bus (HSSB)


    • Changed the minimum Device ID from 1 to 0.


    Lufkin Modbus


    • Fixed a Communication Serialization defect that prevented the driver from releasing communication control when there were many memory and/or Write Only tags with scan rates.


    Mitsubishi Ethernet


    • Corrected issues that prevented the Synchronization Method from persisting. Fixed an issue where the Time and Date Synchronization dialog was not being updated correctly after the model was changed but had not been applied.



    Modbus Ethernet


    • Added support for Channel Serialization.

      • Note: Channel Serialization is not supported for unsolicited devices or mailbox model types.


    Modbus RTU Serial


    • Added support for Channel Serialization.


    Modbus ASCII


    • Added support for Channel Serialization.


    Siemens S7 Ethernet


    • Added support for the Siemens TIME_OF_DAY (TOD) data type. Exposed the hint for the Siemens “DATE_AND_TIME” (DT) data type.


    SNMP


    • Added the “Port Offset” device property to the Network Analyst sheet and wizard pages.

    • Changed the "Points in Moving Average" key combination shortcut on the Network Analyst sheet and wizard pages from Alt-A to Alt-M.

    • Increased the maximum number of channels from 100 to 256.


    Torque Tool Ethernet


    • Fixed an issue where the driver continuously attempted to reconnect if a device responded with "Client Already Connected".


    UCON (User-Configurable)


    • Fixed high CPU utilization in the Server Runtime caused by the U-CON driver when using cached Write Value commands in unsolicited Ethernet encapsulation mode and no socket connection exists.


    Weatherford 8500 Serial


    • Fixed a Communication Serialization bug that prevented the driver from releasing communication control when there were many memory and/or Write only tags with scan rates.


    Yokogawa DX Ethernet


    • Added a new warning for situations where the model series received from the device does not match the model that was configured in the device.

    • Reverted the behavior that was introduced in the 5.4 server release that reported an error and did not allow unsupported model series.

    • Reverted to the previous behavior that ignored the invalid model series returned from the device. Set the model series to that of the configured model in this situation.

    • Added a new warning for situations where the model series is unsupported.

    • Displayed the model series string in the Model Tag even if it doesn't match a series in the list. Previously, the tag displayed Unknown with Bad quality when the model series was not supported.

    • Added support for AS1 Advanced Security Option.


    Yokogawa MX Ethernet


    • Added support for MX style 3 Firmware.

    • Added tag address “Unit.Firmware” to display the Firmware version information as a string of four hex octets.

    • Reports unit style and module count information to Event Log.

    • Corrected an issue where error 'FFFF' was erroneously reported on tags when a DNR was reported.

    Download 176,31 Kb.
    1   ...   9   10   11   12   13   14   15   16   ...   20




    Download 176,31 Kb.

    Bosh sahifa
    Aloqalar

        Bosh sahifa



    TOP Server Release Notes (5.8.109.0) February 21, 2012

    Download 176,31 Kb.