Kompyuter tarmoqlari” fanidan bajargan 2-Amaliy ishi MavzuBajardi: Satimov Ne`matjon Tekshirdi: Xusanov O‘rol Toshkent – 2023 Laboratoriya ishi № 2Ishdan maqsadVariant IP manzilSwitch>enable Switchconfigure terminalFa0/17, Fa0/18, Fa0/19, Fa0/20 Fa0/21, Fa0/22, Fa0/23, Fa0/24 2 A_blok active 3 B_blok active 1002 fddi-default act/unsupSwitch(config)int fa 0/9 Switch(config-if)switchport mode acces Switch(config-if)switchport acces vlan 2 Switch(config-if)exitSwitch(config)end show vlan brief buyrug’i bilan natijani ko’ramiz. Switchshow vlan brief VLAN Name Status PortsFa0/11, Fa0/12, Fa0/13, Fa0/14 Fa0/15, Fa0/16, Fa0/17, Fa0/18 Fa0/19, Fa0/20, Fa0/21, Fa0/22 Fa0/23, Fa0/24 2 A_blok active Fa0/9 |
Dasturiy injinering” fakulteti nwk010-3-guruh talabasi Satimov Ne`matjonning
|
Sana | 31.10.2023 | Hajmi | 1.18 Mb. | | #92045 |
Bog'liq 2-amaliy Dars ishlanma 2 CHQBT, 5-Мавзу, Lutfullayeva Dildora . (1), teaching-pronunciation, 12, Mashinasozlik texnologiyasi asoslari. Mirzayev A. Sotvoldiyeva A, 1111111111111 (2), O\'zbekistonda soliq islohotlarining ustuvor yo\'nalishlari kurs ishi, МАЪЛУМОТНОМА, 8, b71bd6491cecacd332fdbb790f7eef1e Tabiiy gazni ajratishda i ssiqlik almashinuvi jihozlarining qo‘llanilishi va ularning ishonchliligini ta’minlash, 1“Innovatsion iqtisodiyot” faniga kirish, Flash Presentation TheclimateandwildlifeoftheUSA. 11 33 1, zakovatBu sahifa navigatsiya:
- Kompyuter tarmoqlari” fanidan bajargan 2-Amaliy ishi Mavzu
- Bajardi: Satimov Ne`matjon Tekshirdi: Xusanov O‘rol Toshkent – 2023 Laboratoriya ishi № 2
- Ishdan maqsad
- Variant IP manzil
- Switch>enable Switchconfigure terminal
- Fa0/17, Fa0/18, Fa0/19, Fa0/20 Fa0/21, Fa0/22, Fa0/23, Fa0/24 2 A_blok active 3 B_blok active 1002 fddi-default act/unsup
- Switch(config)int fa 0/9 Switch(config-if)switchport mode acces Switch(config-if)switchport acces vlan 2 Switch(config-if)exit
- Switch(config)end show vlan brief buyrug’i bilan natijani ko’ramiz. Switchshow vlan brief VLAN Name Status Ports
- Fa0/11, Fa0/12, Fa0/13, Fa0/14 Fa0/15, Fa0/16, Fa0/17, Fa0/18 Fa0/19, Fa0/20, Fa0/21, Fa0/22 Fa0/23, Fa0/24 2 A_blok active Fa0/9
O‘ZBEKISTON RESPUBLIKASI AXBOROT TEXNOLOGIYALARI VA KOMMUNIKATSIYALARINI RIVOJLANTIRISH VAZIRLIGI
MUHAMMAD AL‑XORAZMIY NOMIDAGI TOSHKENT AXBOROT TEXNOLOGIYALARI UNIVERSITETI
Muhammad al-Xorazmiy nomidagi Toshkent axborot texnologiyalari universiteti
“Dasturiy injinering” fakulteti NWK010-3-guruh talabasi Satimov Ne`matjonning
“Kompyuter tarmoqlari” fanidan bajargan
2-Amaliy ishi
Mavzu: CISCO KALITLARINING BUYRUQ INTERFEYSI BILAN ISHLAB CHIQISH VA BIRINCHI KONFIGURATSIYANI O'RNATISH. CISCO PACKET TRACERDA LAN TARMOG’INI LOYIHALASH VA QURISH.
Bajardi: Satimov Ne`matjon
Tekshirdi: Xusanov O‘rol
Toshkent – 2023
Laboratoriya ishi № 2
CISCO KALITLARINING BUYRUQ INTERFEYSI BILAN ISHLAB CHIQISH VA BIRINCHI KONFIGURATSIYANI O'RNATISH. CISCO PACKET TRACERDA LAN TARMOG’INI LOYIHALASH VA QURISH
Ishdan maqsad: Ma'lumotlar tarmoqlarida IP-manzillashni o'rganish. Sinfli va sinfsiz IP manzillardan foydalanish bo'yicha amaliy ko'nikmalarga ega bo'lish.
9-variant
Variant
|
IP manzil
|
9
|
147.107.2.89/8
|
1 ta switch va 2 ta kompyuter olamiz. Kompyuterlarni switchning 9-va 10-portlariga ulaymiz.
Switchning terminaliga kiramiz.
Switch>enable
Switch#configure terminal
Yozib sozlamalariga kiramiz.
Switch(config)#vlan 2
Switch(config-vlan)#name "A_blok"
Switch(config-vlan)#exit
Switch(config)#vlan 3
Switch(config-vlan)#name "B_blok"
Switch(config-vlan)#exit
Switch(config)#end
vlan 2 va vlan 3 ga alohida alohida nom beramiz. “A_blok” va “B_blok” deb nomladim.
show vlan buyrug’i bilan natijani ko’rishimiz mumkin.
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active Fa0/1, Fa0/2, Fa0/3, Fa0/4
Fa0/5, Fa0/6, Fa0/7, Fa0/8
Fa0/9, Fa0/10, Fa0/11, Fa0/12
Fa0/13, Fa0/14, Fa0/15, Fa0/16
Fa0/17, Fa0/18, Fa0/19, Fa0/20
Fa0/21, Fa0/22, Fa0/23, Fa0/24
2 A_blok active
3 B_blok active
1002 fddi-default act/unsup
1003 token-ring-default act/unsup
1004 fddinet-default act/unsup
1005 trnet-default act/unsup
Sozlamalariga yana kirib olamiz.
FastEthernet 9-portini vlan 2 va FastEthernet 10-portini vlan 3 ga bog’laymiz.
Switch(config)#int fa 0/9
Switch(config-if)#switchport mode acces
Switch(config-if)#switchport acces vlan 2
Switch(config-if)#exit
Switch(config)#int fa 0/10
Switch(config-if)#switchport mode acces
Switch(config-if)#switchport acces vlan 3
Switch(config-if)#exit
Switch(config)#end
show vlan brief buyrug’i bilan natijani ko’ramiz.
Switch#show vlan brief
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active Fa0/1, Fa0/2, Fa0/3, Fa0/4
Fa0/5, Fa0/6, Fa0/7, Fa0/8
Fa0/11, Fa0/12, Fa0/13, Fa0/14
Fa0/15, Fa0/16, Fa0/17, Fa0/18
Fa0/19, Fa0/20, Fa0/21, Fa0/22
Fa0/23, Fa0/24
2 A_blok active Fa0/9
3 B_blok active Fa0/10
1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active
Switch#
Endi kompyuterlarga IP address beramiz.
147.107.2.89 IP sini ikkala kompyuterga bersak ham endi ular ishlayapti. Chunki alohida alohida portga ajratdik.
|
| |