Conclusion 
 
This academic piece of paper presents a comparative 
study of a two hybrid renewable energy systems, one 
connected to the local grid (on-grid) and the other is 
standalone (off-grid), without taking the influence of 
sensitive variables into consideration. This study occurred 
in Duhok , north of Iraq due to ease of solar and wind data 
access. The simulation results of the proposed system 
proved that hybrid solar-wind energy system connected to 
the local grid is most cost-effective than off-grid design for 
the similar load. Our hybrid system is better cost efficient 
than Duhok residential power grid, as our system cost unit 
is (0.0618 $\kWh) while Duhok residential electricity is 
0.1$\kWh. 
 
Acknowledgements
 
Authors are very grateful to the (Mosul university\ 
college of science
and Nineveh University / College of 
Electronics Engineering) for their provided facilities, which 
helped to enhance the quality of this work. 
 
Authors: Mustafa Hussein Ibrahim, Depatment of New and 
Renewable Energy, College of Science, Mosul University, Iraq, E-
mail: MustafaHussein@uomosul.edu.iq ; Muhammed A Ibrahim, 
Department of Systems and Control, College of Electronics 
Engineering, Ninevah University, Iraq, E-mail: 
muhammed.ibrahim@uoninevah.edu.iq . 
REFERENCES 
[1]
Razak N, Othman M. Bin, Musirin I. Optimal sizing and 
operational strategy of hybrid renewable energy system using 
HOMER. 4th International Power Engineering and Optimization 
Conference (PEOCO). Selangor, Malaysia. 2010; 1: 495-501. 
[2]
Kharrich M, Mohammed O, Kamel S, Selim A, Sultan H
Akherraz M, Jurado F. Development and implementation of a 
novel optimization algorithm for reliable and economic grid-
independent hybrid power system. Applied Sciences 
(Switzerland). 2020; 10(18). 
[3]
Al-hafidh M, Ibrahem M. Zero Energy House in Iraq. 
International Journal of Inventive Engineering and Sciences
2014; 2(7). 
[4]
Reno M, Hansen C. Global horizontal irradiance clear sky 
models implementation and analysis. Sandia National 
Laboratories. Report number: 2389. 2012.
[5]
Vendoti S, Muralidhar M, Kiranmayi, R. Modelling and 
optimization of an off-grid hybrid renewable energy system for 
electrification in a rural area. Energy Reports. 2020; 6(2352). 
[6]
The Atmospheric Science Data Center (ASDC). (2021, May 7). 
NASA Earth Science Data. 
https://earthdata.nasa.gov/eosdis/daacs/asdc.


PRZEGLĄD ELEKTROTECHNICZNY, ISSN 0033-2097, R. 97 NR 9/2021 143 
[7]
Alsharif M. Optimization design and economic analysis of 
energy management strategy based on photovoltaic/energy 
storage for heterogeneous cellular networks using the HOMER 
model. Solar Energy. 2017; 147(38). 
[8]
Sarkar J, Khule S. A study of MPPT schemes in PMSG based 
wind turbine system. International Conference on Electrical, 
Electronics, and Optimization Techniques (ICEEOT). Chennai, 
India. 2016; 1: 100–105.
[9]
Tigabu M, Guta D, Admasu B. Economics of Hydro-Kinetic 
Turbine for off-grid Application: A Case Study of Gumara River, 
Upper Blue Nile, Amhara, Ethiopia. International Journal of 
Renewable Energy Research-IJRER. 2019; 9(3). 
[10]
Reichling J, Kulacki F. Utility scale hybrid wind-solar 
thermal electrical generation: A case study for 
Minnesota. Energy. 2008; 33(4). 
[11]
Fantidis J, Bandekas D, Vordos N. Study of a 
Wind/PV/Battery hybrid system - Case study at Plaka in 
Greece. Journal of Engineering Science and Technology 
Review. 2015; 8(3).
[12]
Sanni S, Ibrahim M, Mahmud I. Potential of Off-grid Solar 
PV/Biogas Power Generation System: Case Study of Ado Ekiti 
Slaughterhouse. International Journal of Renewable Energy 