TOP Server Release Note (5.2.133.0) February 18, 2010
| bet | 19/20 | Sana | 25.09.2020 | Hajmi | 176,31 Kb. | | #11681 |
TOP Server Release Note (5.2.133.0) February 18, 2010 -
Added support for OPC UA Configuration management
-
From the Settings | Configuration tab added ability to enable remote connections to support Exchange feature of UA Configuration Manager (secure by default).
Configuration Interface -
Added support for OPC UA Project Configuration
-
Fixed failure to close the channel diagnostics window attached to a recently deleted channel.
-
Fixed "Runtime Update Failed" messages following tag duplication, object paste.
-
Fixed the print button in the event log print preview.
-
Resolved issue where the DCOM setting ‘Identity’ for the Configuration Client was not retained when "The launching user" option was selected.
-
Updated project handling logic for case where a Read/Write user was not given a warning to save a modified project offline before loading new project.
-
Updated project handling logic to prevent an update to the Runtime when connecting the Configuration as a Read Only user.
-
Issue in the 5.1 release only, fixed failure to launch the server runtime process from the Configuration client if the Runtime is configured for interactive use and UAC is enabled.
-
Updated the Alias browse GUI to eliminate the dependence on the parent dialog's check box with corresponding help update to better describe the “Show systems tag group:” checkbox.
-
Added enable/disable checkbox for A&E project settings.
Runtime Interface -
New OPC UA server interface V1.01 supporting optimized binary TCP.
-
Improved DDE server capability when running as a service, to prevent MS Excel DDE client stability issues. (Requires interact with desktop to be enabled.)
-
Fixed failure to apply Alias scan rate override to items added via the FastDDE/SuiteLink native interface.
-
Added the ability for a user to specify the 'default' project to use the next time the runtime is started. The Runtime will look for user-supplied project.xml or project.opf file in the same directory as the default.opf at server startup and reinitialize.
-
Fixed problem were no client update was being generated from the OPC layer upon item state transition from inactive to active.
Event Log Components / Utilities
OPC UA Configuration Manager
-
New utility which always installs due to install of OPC UA server interface.
OPC A&E Server
-
Fixed a COM error when the server forced client deletion. The error resulted in stability issues with the runtime.
License Utility
-
Several minor cosmetic updates to the UI.
-
Added the following warning text to the software activations page: “Caution: Multiple licenses of the same product cannot be activated on one machine. Attempting to do so will result in the loss of the license.”
OPC Quick Client
-
Enhanced the Quick Client to better support international value formats where a comma is used instead of a decimal point for floating point numbers.
Install -
Add the ability for the user to override the default root for application data. This enhancement is for users of systems (i.e. embedded OS) where a “SharedApplicationDataDirectory” may not have write privileges or may not exist. When performing un-installs, the product.ini file will not be deleted.
-
Fixed issue found internally where a Windows SxS error is recorded in the application event log during product installation.
-
Enhanced digital signature verification logic to no longer depend on CAPICOM (which is deprecated in Windows 7). Removed CAPICOM from install.
-
Resolved issue with 5.1 install where an upgrade from 5.0 to 5.1 caused the process mode to change from Interactive to Service.
-
Make installing the A&E Custom Alarms Plug-in optional, but give all users the OPC A&E server interface (event log messages to A&E clients) by default.
-
Updated hardware key drivers (HASP SRM command line installation) to support Windows 7. Tested with 32/64 bit operating systems.
-
Replaced old SimDemo.opf sample project with a more modern sample.
-
Install on Windows 2000 will prompt user to reboot and restart install after VS2005 installed.
Plug-ins
A&E Custom Alarms
DataLogger Plug-In
-
Fixed issue where deadlock could occur after starting/stopping a log group.
-
Fixed an issue where table creation with Oracle databases was not working.
Drivers
All Drivers
-
Improved device read queue logic to prevent potential deadlock scenario. This issue was found during internally testing.
Allen-Bradley ControlLogix Ethernet
-
Modified the driver to support locale-specific multi-byte strings.
-
Resolved an issue with Auto Tag Generation that occurred if a project correlation error was detected.
-
Increased the maximum number of Programs supported from 512 to 1024.
-
Fixed application exception that can occur when multiple Logix Array elements are added and removed at random, followed up by a project upload (due to inactivity, change in project, etc).
BACnet
-
Modified driver to not repeatedly request the "Segmentation Supported" property from a device if the device returns an error to that request.
-
Fixed ATDBG when the device responds with an error to the Read Property: ALL command.
-
Corrected a problem with parsing a NotificationClass Object. This was causing ATDBG to fail with an internal test device, and generating default tags.
-
Resolved issue with permanent COV subscriptions.
-
Enhanced COV Subscription Request handling to improve performance
Cutler-Hammer ELC Ethernet
-
Fixed issue with write-only tags introduced in 5.0. The value of the tag was not updating when a value was written to it. The correct value was written to the device, just not displayed in the data client.
Cutler-Hammer ELC Serial
-
Fixed issue with write-only tags introduced in 5.0. The value of the tag was not updating when a value was written to it. The correct value was written to the device, just not displayed in the data client.
Dataforth IsoLynx
-
Fixed issue introduced in 5x where reconnect to device after a cable pull can take minutes instead of seconds as in V4.x version of driver.
GE Ethernet
-
Fixed issue where PACSystem UDT booleans were not being read or written properly
GE Focas1 Ethernet
-
Fixed address parser problem introduced with addition of CNC status info tags.
Honeywell HC900 Ethernet
-
Replaced broken "Regenerate imported tags" checkbox with a regenerate button. The regenerate button gives the same intended functionality as the "Regenerate imported tags" checkbox.
-
Fixed issue where the driver did not support proper importation of certain digital addresses such as digital floats.
Idec Serial
Mettler Toledo Serial
-
Added write-only Booleans CTPZ commands (Clear, Tare, Print, Zero).
-
Enabled Unsolicited Ethernet Encapsulation.
Modbus Ethernet
-
Fixed issue with write-only tags introduced in 5.0. The value of the tag was not updating when a value was written to it. The correct value was written to the device, just not displayed in the data client.
-
Allow global settings that control unsolicited port and protocol to change on the fly.
Modbus Serial
-
Fixed issue with write-only tags introduced in 5.0. The value of the tag was not updating when a value was written to it. The correct value was written to the device, just not displayed in the data client.
Omron FINS Ethernet
-
Fixed thread synchronization issue which could result in intermittent stale communications for certain channels in multi-channel projects
OPC UA Client Driver
Opto 22 Ethernet
-
Fixed issue with processing "Object not found" Errors when using "CONT over Ethernet TCP/IP" Communications Protocol.
SattBus Serial
-
Resolved issue where the driver was not removing tag(s) from its tag table when the client application disconnects.
Siemens TCPIP Ethernet
-
Fixed issue where the Runtime could terminate after multiple writes to bit addresses.
-
Resolved issue introduced in 5.1 release where device-level _System tags (_Error,_NoError) were not working properly.
Sixnet UDR Serial
-
Fixed access violation when the driver dll is unloaded and reloaded.
SNMP
-
Fixed Trap event handler to receive Traps correctly after IP changes when the device is in use (has active items).
-
Disabled Scan Floor and Lock controls on Device Communications property page if the device is in use (has active items).
U-CON
-
Added ability to select any character as the escape character for a selected group of control characters to the Handle Escape Character command.
-
Fixed issue where format properties for commands were not preserved in the transaction editor on loading a command's properties.
|
| |