All ports can be limited to the internal network, if the BIS-Server is located there
|
bet | 3/10 | Sana | 31.03.2021 | Hajmi | 171,58 Kb. | | #13816 |
All ports can be limited to the internal network, if the BIS-Server is located there.
Allow the following BIS standard ports for inbound communication with the login server:
25805, 25806, 25902 and 25923 (TCP)
For internal communication (“localhost” to “localhost”) the BIS standard ports (25800 – 27050 (TCP)) are necessary.
In case Video Engine is used:
It is recommended that the BISClient.exe is allowed in the Windows Firewall.
Program settings (BISClient.exe):
For Windows XP:
Start the Windows Firewall via “Start” – “Settings” – “Control Panel” – “Windows-Firewall”
Select tab “Exceptions” and add the following program:
For Windows 7, Windows Server 2008 R2:
Start the Windows Firewall via “Start” – “Control Panel” – “Windows-Firewall”
Select “Advanced settings”, do the following for Inbound Rules
Add new Rule
Rule Type: Program
Allow the following program:
For all Operating Systems:
C:\Program Files\MgtC\BISClient.exe
(in case of Windows 7 64 Bit or Windows Server 2008 R2 64 Bit the path can be C:\Program Files (x86)\MgtC\BISClient.exe)
|
| |