Thin catheter administration




Download 1,5 Mb.
bet134/654
Sana03.01.2022
Hajmi1,5 Mb.
#14803
1   ...   130   131   132   133   134   135   136   137   ...   654
Thin catheter administration: Use a 4 French end-hole catheter marked approximately 1.5 cm above one end. Connect a syringe and catheter prefilled with surfactant preparation. While the infant is breathing via nasal CPAP, introduce laryngoscope and insert catheter using Magill forceps up to the mark on the catheter. Secure tube position and remove laryngoscope. With the infant’s mouth closed, instil surfactant during 30 to 120 seconds by mini-boluses. In cases of apnoea or bradycardia, perform positive pressure ventilation until recovery.

Monitoring

Continuous oxygen saturation and cardiorespiratory monitoring.