    cleaning of fiber removal, which is explained by the extended zone of active fiber removal and 
    the long time of the saw teeth in it. When designing air-assisted fiber removal devices, it is 
    necessary to try to increase the active contact time of the saw teeth with the working air stream 
    [6-7]. 
    According to research, the ejection coefficient for normally adjusted exhaust devices is Ke 
    = 1.9 ÷ 2 for the lower exhaust, and K_

    = 1.5 ÷ 1.6 for the upper one. 
    Fig.7. The air gap system is 5 mm and the distance to the saw tooth is 45 mm 
    The discharge capacity of existing devices, as can be seen from these data, is extremely high, 
    which significantly increases the need for filter surfaces necessary for exhaust air treatment [8-
    9]. The air spray system showed a result of 53 meters/second at a distance of 45 mm to the notch 
    5 mm saw (Figure 7). 
     
    Fig.8. The air gap system is 5 mm and the distance to the saw tooth is 65 mm 
     
    The air-push system showed 49 meters/second at a distance of 65 mm to the notch 5 mm 
    saw. 


    Namangan Institute of Engineering and Technology
     
    nammti.uz 
    10.25.2023
    Pg.576 
    Fig.9. The air gap system is 5 mm and the distance to the saw tooth is 85 mm 
     
    The air spray system showed a result of 33 meters / second when the distance to the slot 5 
    mm saw was 85 mm. 
    Modeling of air blowing chamber and fiber receiving chamber 
    We determine the surface of the inlet pipe b=250mm x h=250mm = 25cm x 25cm 
    S= 25x25=625cm
    2
    We determine the surface of the exit slot b=1500mm x h=5mm =150cm x 0.5cm 
    S=150cm x 0.5cm= 75cm
    2
    Characteristics of the VTS-10 ventilator 
    The fan speed is 1500 metr/min
    Pressure P=1800Pa 
    Work volume L=3450m
    3
    /hour 
    𝑣
    𝑘
    =
    𝐿
    (3600 ∙ 𝑏 ∙ ℎ)
    =
    3450
    (3600 ∙ 0,25 ∙ 0,25)
    = 15,33𝑚𝑒𝑡𝑟 𝑠𝑒𝑐
     
    𝑣
    𝐶𝐻
    =
    𝐿
    (3600∙𝑏∙ℎ)
    =
    3450
    (3600∙1,5∙0,005)
    = 127𝑚𝑒𝑡𝑟 𝑠𝑒𝑐
     
    We are completely satisfied with the characteristics of the VTS-10 fan, since the air blowing 
    system and the intake system are two sets in our new construction gin machine.The air spray 
    system showed a result of 53 meters/second at a distance of 45 mm to the notch 5 mm saw. The 
    air-push system showed 49 meters/second at a distance of 65 mm to the notch 5 mm saw. The 
    air spray system showed a result of 33 meters / second when the distance to the slot 5 mm saw 
    was 85 mm. We extended the intake pipe from the fan to allow air to flow through the air intake 
    slot at a speed of 63 meters per second, and we achieved a high pressure build-up in the air intake 
    system. In our new construction machine, the air blowing system collects the air flow coming 
    from the fan through a rectangular tube of b=250mm x h=250mm and collects it in the whole air 
    blowing system through a slot with a size of S=150cm x 0.5cm= 75cm2. sends The air flow comes 
    out of the slot of the air blowing system at a speed of 63 meters per second and removes the 
    fiber from the saw teeth and transfers it to the air intake system. In this case, we take the 
    diameter of the guide pipe as 105 mm. 